Rebound Hammers
Precision non-destructive testing (NDT) instruments for evaluating the compressive strength and uniform quality of in-situ concrete, mortar, and masonry per IS 13311 (Part 2), ASTM C805, and EN 12504-2.
Concrete Test Hammer Range
Authorized supplier of Langry concrete test hammers. Each hammer is engineered with precision internal springs, hardened wear-resistant aluminum casings, and calibrated against certified test anvils.
Langry Testing Anvil (GZ-I / GZ-II / Portable)
High-precision calibration test anvil manufactured from premium tool steel hardened to HRC 60 ± 2. Mandatory requirement per IS 13311-2 and ASTM C805 for daily calibration verification before and after testing.
Rebound Hammer Selection Matrix
Compare verified technical parameters across the official Langry rebound hammer series to select the optimal model for your application.
| Model | Hammer Type | Impact Energy | Strength Range | Spring Stiffness | Anvil Value | Primary Application |
|---|---|---|---|---|---|---|
| RH225-B | Digital (OLED + Bluetooth) | 2.207 J | 10 – 60 MPa | 785 ± 30 N/m | 80 ± 2 | General structural concrete with on-site paperless reporting |
| RH225-A | Mechanical Pointer (Type N) | 2.207 J | 10 – 60 MPa | 785 ± 30 N/m | 80 ± 2 | Columns, slabs, beams, building frames (IS 13311-2 standard) |
| RH450-A | High Strength Mechanical | 4.500 J | 60 – 100 MPa | 900 ± 40 N/m | 88 ± 2 | High-rise pillars, mega bridge girders, high-performance concrete |
| RH550-A | Heavy-Duty Mechanical | 5.400 J | 60 – 120 MPa | 1000 ± 50 N/m | 88 ± 2 | Dams, hydraulic powerhouses, deep tunnel linings, UHPC |
| RH75-A | Low Energy (Type L) | 0.735 J | 10 – 50 MPa | 260 ± 15 N/m | 74 ± 2 | Clay bricks, lightweight aggregate concrete, thin precast slabs |
| RH20-A | Mortar Type (Type M) | 0.196 J | 1.0 – 25 MPa | 100 ± 5 N/m | 60 ± 2 | Building mortar seams, wall rendering, plaster strength verification |
Testing Methodology & Compliance Guide
Rebound hammer testing estimates compressive strength by driving an elastic impact plunger against the concrete surface and measuring the rebound distance of the spring-controlled mass.
- Surface Preparation: Use the supplied carborundum grinding stone to eliminate surface carbonation, laitance, or rough coatings before striking.
- Impact Matrix: Execute 10 to 12 impact readings spaced at least 25 mm apart per test location as specified in IS 13311 (Part 2).
- Angle Correction: Digital models (like the RH225-B) automatically perform trigonometric impact angle corrections (horizontal, upward, or downward).
- Anvil Verification: The rebound hammer must produce readings within the certified tolerance (e.g. 80 ± 2 for Type N) on a verified steel testing anvil.